Fractures of the Distal Tibia Treated with Polyaxial Locking Plating
Hong Gao MD, Chang-Qing Zhang MD, PhD, Cong-Feng Luo MD, PhD, Zu-Bin Zhou MD, Bing-Fang Zeng MD
Original Article
Volume 467,
Issue
3
/
March ,
2008
Abstract on SpringerLink |
Full article HTML |
Full article PDF
Download Citation
Abstract
We evaluated the healing rate, complications, and functional outcomes in 32 adult patients with very short metaphyseal fragments in fractures of the distal tibia treated with a polyaxial locking system. The average distance from the distal extent of the fracture to the tibial plafond was 11 mm. All fractures healed and the average time to union was 14 weeks. Six patients (19%) reported occasional local disturbance over the medial malleolus. There were two cases of postoperative superficial infections and evidence of delayed wound healing. Using the American Orthopaedic Foot and Ankle Society ankle score, the average functional score was 87.3 points (of 100 total possible points). Our results show the polyaxial locking plates, which offer more fixation versatility, may be a reasonable treatment option for distal tibia fractures with very short metaphyseal segments.
Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.